Physitemp-instruments BFS-30MP Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Physitemp-instruments BFS-30MP. Physitemp Instruments BFS-30MP User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PHYSITEMP INSTRUMENTS INC
154 Huron Avenue
Clifton NJ 07013 USA
Tel: 973-779-5577
Fax: 973-779-5954
OPERATING MANUAL
EB FRONTIS EB BFS-MP 6310
BFS-MP SERIES FREEZING STAGES
Models BFS-3MP, BFS-5MP, BFS-30MP
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - BFS-MP SERIES FREEZING STAGES

PHYSITEMP INSTRUMENTS INC154 Huron AvenueClifton NJ 07013 USATel: 973-779-5577Fax: 973-779-5954OPERATING MANUALEB FRONTIS EB BFS-MP 6310BFS-MP SERIES

Pagina 2 - OPERATING INSTRUCTIONS

BFS/MP SERIES THERMAL STAGES1.0 GENERAL DESCRIPTION1.1 Physitemp manufactures three freezing stages for use with microtomes. All stages operate in the

Pagina 3 - PUMP AND TANK UNIT, PTU-3

WARNING! DO NOT USE DRY ICE ON TOP OF THE STAGESeveral customers have reported using Dry Ice (CO2) to speed up thefreezing of tissue specimens mounted

Pagina 4 - EB BFS-MP 6310 04/04

OPERATING MANUALBFS-MP FREEZING STAGESFOR MICROTOMESBFS-3MP, BFS-5MP, BFS-30MPCONTENTSSECTION PAGE1.0 GENERAL DESCRIPTION 22.0 UNPACKING AND CHECKING

Pagina 5

APPENDIX 2OPERATING INSTRUCTIONSECV-1 ELECTRICALLY OPERATED SOLENOID VALVEThe ECV-1 is supplied with an AC line cord and 12 VDC desktop power supply.1

Pagina 6

APPENDIX 1OPERATING INSTRUCTIONS FOR PHYSITEMP PUMP AND TANK UNIT, PTU-31. Unscrew cap. Fill reservoir with 5 gallons of distilled water.2. Connect ex

Pagina 7

7.0 MAINTENANCE, WARRANTY AND SERVICE7.1 MAINTENANCEThe stage needs no maintenace at all. It may be cleaned as necessary with a soft cloth, water or d

Pagina 8 - FRONT PANEL CONTROLS

6.0 SPECIFICATIONS6.1 CONTROLLEROperating Range: BFS-3MP and 5MP: -35°C to ambientBFS-30MP: -40°C to ambientDigital Readout Resolution: 0.1°CAccurac

Pagina 9 - CONNECTIONS

collar in an anti-clockwise direction. An ohmmeter will be required to make several readings on thestage connector. Once the connector has been remove

Pagina 10 - BFS/MP SERIES THERMAL STAGES

4.7 REMOVING SPECIMEN FROM STAGEPress the Freeze/Thaw switch and hold in the QUICK THAW position for a few seconds. Allow thestage to warm up until sp

Pagina 11

4.0 OPERATING INSTRUCTIONS4.1 Ensure that the POWER Switch on the rear panel of the controller is in the OFF position4.2 Check the VOLTAGE SELECTOR SW

Pagina 12 - FOR MICROTOMES

3.0 SETTING UP THE SYSTEMThis section gives instructions for set-up if the equipment is to be used with tap water: If a Pump and Tank Unit is to be us

Comentarios a estos manuales

Sin comentarios